Class 100 Laminar Flow Hood

Class 100 Laminar Flow Hood
Details:
The class 100 laminar flow hood is an air purification device that provides a local high-cleanliness working environment. The core principle is to allow air to pass through a high-efficiency filter in a unidirectional, uniform, and parallel manner, thereby effectively controlling the number of dust particles or microorganisms in the working area and protecting the work object from contamination.
Send Inquiry
Description
Send Inquiry

Product Definition

 

Classification by Airflow Direction:

1. Vertical flow laminar flow hood: air is blown vertically downward from the top HEPA/ULPA filter, across the work surface, and then exhausted from the front or bottom of the work surface (part of it will be circulated and part of it will be exhausted).

 

2. Horizontal flow laminar flow hood: air is blown horizontally forward from the HEPA/ULPA filter on one side, across the work surface, and then exhausted from the front of the work surface.

Classification by Installation Method:

1. Ceiling mounted laminar flow hood: Suspended from the ceiling, it takes up no floor space and is suitable for localized enhanced purification in large clean areas (such as operating rooms and workbenches in electronics workshops).

 

2. Vertical laminar flow hood: Comes with a built-in stand or a floor-standing design, allowing for flexible movement or fixed installation. It is suitable for temporary or localized applications requiring high cleanliness (such as laboratory workbenches and food packaging lines).

 

Application

 

 

Life science laboratories

Aseptic operations (such as microbial inoculation, cell culture, tissue processing), PCR loading, electrophoresis gel preparation, precision weighing, etc.

01

Pharmaceuticals and biotechnology

Sterile drug packaging, filling (in a higher level clean room background), sterility inspection, culture medium preparation, etc.

02

Hospitals and clinics

Dispensing operations and sterile preparations in intravenous drug dispensing centers (PIVAS).

03

Electronics industry

Assembly and inspection of precision electronic components and optical components.

04

Food and cosmetics

Serile or clean packaging, microbiological testing.

05

 

Air Flow Hood
Air Flow Hood1

 

Parameter Table

 

 

Size
L*W*H(mm)
1035*730*600 1340*730*600 1340*2090*600
HEPA Filter Size 915*610*93mm
-1pc
1220*610*93mm
-1pc
1220*610*93mm
-1pc
Filter Grade G4(EN779)
H14(EN1822)
G4(EN779)
H14(EN1822)
G4(EN779)
H14(EN1822)
Operational efficiency 180W 240W 680W
Box material SUS304 SUS304 SUS304
Power supply AC 220V/1PH AC 220V/1PH AC 220V/1PH

Cleanliness Level
ISO Class5
(Level 100)
ISO Class5
(Level 100)
ISO Class5
(Level 100)

Average wind speed
0.36-0.54m/s 0.36-0.54m/s 0.36-0.54m/s
 Support Customized Size

 

Laminar Flow Bench
 

Laminar Flow Bench

 

 

Product Advantages

 

 

01/

High cleanliness: Provides ISO 5 (level 100) one-way clean air.

02/

Equipped with differential pressure alarm and automatic wind speed adjustment functions.

03/

Low energy consumption, low noise, long life, stable and reliable quality.

04/

Low resistance, high efficiency, and liquid tank sealing design.

05/

Negative pressure structure design to ensure no leakage risk.

06/

The class 100 laminar flow hood can be used as a single unit or in a connected system, providing a variety of control solutions to effectively reduce operating costs.

07/

Equipped with LED touch screen control and differential pressure display function to monitor the operating status of the equipment in real time.

08/

Modular design, reasonable layout, easy to install and maintain on site.

 

Working Principle

 

 

 

Before operation

Turn on the fan and run it for 15-30 minutes for self-cleaning. Clean and disinfect the operating table. Prepare all necessary items to reduce frequent arm movement during operation.

 

During operation

The movements should be as gentle as possible, and avoid rapid movements that interfere with laminar flow. Objects and work areas should be placed as downstream as possible in the clean air flow direction (vertical flow: away from the operator side; horizontal flow: away from the air inlet side).

 

After operation

Clean and disinfect the table. Keep the fan running for a while before turning it off. Clean the table, side walls and bottom grille regularly.

 

Maintenance

Replace the pre-filter regularly. Replace the high-efficiency/ultra-high-efficiency filter according to the pressure difference indication or usage time (usually 1-3 years, depending on the usage environment and frequency), and have it checked by a professional (such as wind speed, cleanliness, filter integrity test).

 

Why choose us?
 

Choosing us is not only about buying equipment, but also about obtaining:

Certainty of 100% cleanliness compliance

Laminar flow quality verified by data.

Optimal solution for total cost of ownership

Energy saving and consumption reduction + long life design.

Peace of mind with zero compliance risk

Complete certification + clear responsibilities

Quality verification

Filter PAO/DOP scanning leak detection (99.999% no leakage).

 

Hot Tags: class 100 laminar flow hood, China class 100 laminar flow hood manufacturers, suppliers, factory, Class 100 Laminar Flow Hood, clean room filtration equipment, Laminar Air Flow Bench, laminar flow hood